Recoflex
Technical Details

Minimum inner radiuses on following material combinations
(according to Claudio Waldesbühl, Technical School in Zug)
Material core 18 mm Recoflex Topan 6 mm, one side Furnierleim yes,
Paneling
Adhesive
Application
MDF 4 mm, two sides
1K-polyurethane glue
(foam glue)with restrictions,
beginning with radius of 300 mm
MDF 4 mm +
synthetic resin 1 mm1K-polyurethane glue
(foam glue)yes,
beginning with radius of 300 mm
1K-polyurethane glue
(foam glue)with restrictions,
beginning with radius of 130 mm
Topan 6 mm, two sides
1K-polyurethane glue
(foam glue)yes,
beginning with radius of 130 mm
Kunstharz 1 mm, one side
1K-polyurethane glue
(foam glue)yes,
beginning with radius of 70 mm
Furnier 0,8 mm, two sides
1K-polyurethane glue
(foam glue)yes,
beginning with radius of 50 mm
Furnier 0,8 mm, two sides
yes,
beginning with radius of 50 mm
Topan +
synthetic resin 1 mm1K-polyurethane glue
(foam glue)yes,
beginning with radius of 130 mm
Synthetic resin 1 mm (outside)
+ veneer 0,8 mm (inside)1K-polyurethane glue
(foam glue)
beginning with radius of 50 mm
Attachment of fittings
(according to Claudio Waldesbühl, Technical School in Zug)
Veneered Recoflex panels
| Connection | Execution | Rating |
| Handle | from outside on Recoflex | good, even when srcrewed from outside |
| Cup hinge | screwed | good |
| Cup hinge | screwed and gluedd | very good |
Resistance to screws pulling out axially
(according to Claudio Waldesbühl, Technical School in Zug)
Paneled Recoflex panels
| Recoflex, veneer, foam glue | 210 N | EN 320/93 |
| Recoflex, 4 mm MDF, foam glue | 400 N | |
| MDF-panel, 19 mm | 1.200 - 1.600 N | EN 320/93 |
| 19er particle board, with white finish | 469 N |
Resistance to cup hinges., screwed, pulling out axially
(according to Claudio Waldesbühl, Technical School in Zug)
Paneled Recoflex panels
| Recoflex, veneer, foam glue | 231 N |
| Recoflex, 4 mm MDF, foam glue | 485 N |
| MDF-panel, 19 mm | 429 N |
| 19er particle board, with white finish | 514 N |
Tear-off test for glued-on surfaces
(according to CATAS, Italien)
| Recoflex panels on both sides with HPL plastic laminate | 0,86 Mpa |
| Recoflex panel on both sides with wood veneer | 0,91 Mpa |
| MPF-panel | >1,2 Mpa |
Connection techniques
Reliable strength values can be achieved for Recoflex with nearly all common connection techniques, by using ifneussary foaming adhesive.
Test body; MDF panel, particle board, Recoflex veneered with cherry wood
specific connection per series MDF – Recoflex, particle board – Recoflex, Recoflex - Recoflex
| Connection | Execution | Rating | |
| Lamello 90° | glued | non glued | good |
| Lamello 45° | glued | non glued | good |
| Anchor 90° | glued | non glued |
good |
| Anchor 45° | glued | non glued | good |
| Screwed 90° | glued | good | |
| Screwed 90° | non glued | acceptable | |
| Screwed Surface | Screws with continuous thread are preferable | ||
| Screwed 90° | Recoflex has advantages in edge zone in comparison to MDF | ||
| Butt 90° | glued | non glued | good |
| Butt 45° | glued | non glued | good |
| Butt crossgrained | glued | goot, even without anchors | |
| Butt Surface | glued (untreated) |
Caution on Recoflex – Recoflex: Glue moisture |
